Hybrid Reinforced Concrete Frame Building with Pumice Brick Masonry Infill under Static Lateral Loading

Full Text PDF PDF
Author(s) Akmaluddin | R. S. Saftaningtyas| S. Rawiana | Z. Gazalba
Pages 1482-1491
Volume 2
Issue 8
Date August, 2012
Keywords Infilled frame, openings, stiffness, lateral strength, hybrid

Abstract

The purpose of this study is to investigate the behaviour of hybrid reinforced concrete frame with pumice brick masonry infill under static lateral loading. The term hybrid herein is referred to the frame composed of precast block masonry unit and cast in-place reinforced concrete beams. Parameters considered in this study were frame opening representing doors and windows commonly used in the wall system. Six types of frame namely FS, FB, FDE, FDC, FWE and FWC designation for solid frame, bare frame, frame with door opening at edge, frame with door opening at centre, frame with window opening at edge and frame with window opening at centre respectively were considered. Test results indicated that the FS has a maximum lateral strength greater than that of FB. The lateral strength of FS was about 3.68 of FB. The frames with various openings have lateral strength nearly 2.3 of lateral strength of the bare frame, FB. Ductility factor of the frames varied from 2.4 to 4.92. The residual strength of the frame with openings were varies between 2.33 and 3.35 of the bare frame. The stiffness of the infilled frames with opening were varied from 3.56 to 3.67 of the bare frame. The presence of openings in the infilled frame did not affect the frame stiffness considerably.

< Back to August Issue